• <optgroup id="jwrdj"></optgroup>

  • <span id="jwrdj"></span>
    <optgroup id="jwrdj"><li id="jwrdj"><source id="jwrdj"></source></li></optgroup>

    <span id="jwrdj"><output id="jwrdj"></output></span><acronym id="jwrdj"></acronym>
    <strong id="jwrdj"></strong>
    LG vacuuum pump
    LG vacuuum pump
    Sliding vane rotary vacuuum pump
    2X Sliding vane rotary vacuuum pump
    XD Sliding vane rotary vacuuum pump
    Water ring vacuuum pump
    2SK Two-stage Water ring vacuuum pump
    SK Water ring vacuuum pump
    SZ Water ring vacuuum pump
    2BE Water ring vacuuum pump
    Piston vacuuum pump
    WLW Oil-free vertical Piston vacuuum pump
    Roots vacuuum pump
    ZJ Roots vacuuum pump
    System
    JZJS Roots vacuuum pump System
    JZJX Roots vacuuum pump System
    JZJW Roots vacuuum pump System
    J2SK JSK J2BE Closed cycle System
    Blow Molding Machine
    YX1200 Large hollow blow molding Machine
    WUXI CITY SIFANG VACUUM EQUIPMENT CO.,LTD.
    WEB:http://www.jessicakmiec.com
    E-MAIL:sfpumps@163.com
    TEL:0510-85990421 85990035
    FAX:0510-85993842
    ADD:No.48 Changkang Road, Mashan, Binhu District, Wuxi
     
    Products
    Contents brief introduction
    J2SK JSK J2BE closed cycle units

    Range of use


     J2SK/JSK/J2BE closed cycle units include: vacuum pump, gas-liquid separators, heat exchangers, circulating pumps, accessories such as control systems, etc. Since other working liquid additional to water can be used (i.e. the liquid whose saturation pressure is less than water such as ethylene glycol, transformer oil), the application scope of vacuum pumps is effectively increased and at the same time, the common liquid-ring vacuum pumps such as 2SK, SK, 2BE are prevented form abundant discharge of working liquid in vacuum pump because of the actual application of pumping some gases which would pollute the working liquid, and the use cost of the customers are reduced.
    J2SK, JSK, J2BE closed cycle unit can completely separate the exchange between the technological gases and the air environment and discharge the technological gases into designated locations to avoid damage to the environment. It is especially suitable for the extraction of flammable, explosive and poisonous gases.

    Work Way



     

    Commonly used J2SK types and their main technical parameters
     

     Function 
    Model

    Pumping
    Speed
    (m3/min)

    Ultimate
    Pressure
    (Pa)

    Total
    Power
    (kw)

    Pump
    Rotational
    speed

    (r/min)

    Volume
    of
    diversion

    (L/min)

    Inlet
    Outlet
    Diameter

    (mm)

    Heat
    Transfer
    Area
    (m2)

    Power of
    Circulating
    pump

    (kw)

    J2SK-1.5

    1.5

    3.3×103

    4

    1440

    10~15

    Φ40

    4

    0.18

    J2SK-3

    3

    3.3×103

    7.5

    1440

    15~20

    Φ40

    5

    0.37

    J2SK-6

    6

    3.3×103

    15

    1460

    25~35

    Φ50

    6

    0.37

    J2SK-12

    12

    3.3×103

    22

    970

    40~50

    Φ100

    8

    0.37

    J2SK-20

    20

    3.3×103

    37

    740

    60~80

    Φ125

    12

    1.1

    J2SK-30

    30

    3.3×103

    55

    740

    70~90

    Φ125

    16

    1.1

    Commonly used JSK types and their main technical parameters
     

     Function 
    Model

    Pumping
    Speed
    (m3/min)

    Ultimate
    Pressure
    (Pa)

    Total
    Power
    (kw)


    Pump
    Rotational
    speed

    (r/min)

    Volume
    of
    diversion

    (L/min)

    Inlet
    Outlet
    Diameter

    (mm)

    Heat
    Transfer
    Area
    (m2)

    Power of
    Circulating
    pump

    (kw)

    JSK-1.5

    1.5

    6.7×103

    4

    1440

    10~15

    Φ65

    4

    0.18

    JSK-3

    3

    6.7×103

    7.5

    1440

    15~20

    Φ65

    5

    0.37

    JSK-6

    6

    6.7×103

    15

    1460

    25~35

    Φ100

    6

    0.37

    JSK-12

    12

    6.7×103

    22

    970

    40~50

    Φ125

    8

    0.37

    JSK-20

    20

    6.7×103

    37

    740

    60~80

    Φ150

    12

    1.1

    JSK-30

    30

    6.7×103

    55

    740

    70~90

    Φ150

    16

    1.1


    Commonly used J2BE types and their main technical parameters
     

     Function 
    Model

    Pumping
    Speed
    (m3/min)

    Ultimate
    Pressure
    (Pa)

    Total
    Power
    (kw)


    Pump
    Rotational
    speed

    (r/min)

    Volume
    of
    diversion

    (L/min)

    Inlet
    Outlet
    Diameter

    (mm)

    Heat
    Transfer
    Area
    (m2)

    Power of
    Circulating
    pump

    (kw)

    J2BE-253

    42

    3.3×103

    75

    740

    5.2

    Φ150

    16

    1.1

    J2BE-303

    60

    3.3×103

    90

    660

    8.5

    Φ200

    18

    3

    J2BE-353

    85

    3.3×103

    132

    530

    11.2

    Φ250

    20

    3

    J2BE-403

    110

    3.3×103

    185

    420

    16

    Φ300

    25

    3

     
     